Stereotactic navigation system

A Contract Award Notice
by CAMBRIDGE UNIVERSITY HOSPITALS NHS FOUNDATION TRUST

Source
Find a Tender
Type
Contract (Goods)
Duration
not specified
Value
£200K
Sector
HEALTH
Published
07 Nov 2022
Delivery
not specified
Deadline
n/a

Concepts

Location

Cambridgeshire CC:

Geochart for 1 buyers and 1 suppliers

Description

Stereotactic navigation system with relevant accessories to facilitate planning, conduction, and validation of CT-guided percutaneous ablations.

Total Quantity or Scope

The purchase of a Decision Support and Guidance System for Percutaneous Ablations. This is a single system complete with relevant accessories to facilitate planning, conduction, and validation of CT-guided percutaneous ablations by providing the following capabilities: - Software assisted ablation treatment planning: Tumour targets and surrounding safety margins can be identified and visualized in CT and /or MRI images, applicator trajectories can be planned in 2D and 3D, and desired ablation volumes can be simulated. - Navigation based applicator placement: Applicators (ablation needles) can be safely and accurately placed to the target location with respect to the previously defined trajectory. - Software assisted verification of applicator position: By fusing pre- and peri-operative images, the effective applicator position (in-situ) can be measured and subsequently verified relative to the planned trajectory. If required, treatment and ablation parameters can be adjusted to the actual situation. - Software assisted validation of treatment: Fusion of pre- and postoperative CT images allows for validation of the effective ablation volume relative to the originally planned volume and assists in the decision making towards immediate re-treatment. The system must provide the following essential functionalities: - Import, display and processing of CT and MRI images - Fusion of CT and MRI images to enable treatment of invisible lesions - Trajectory planning for single and multiple applicators - Software assisted treatment planning including o Automatic identification of tumour volume o User assisted selection of safety margin o Database with performance parameters of applicators used in clinic o Simulation of expected ablation volumes as function of time and energy - Guided applicator alignment and insertion using a semi-robotic arm - Automatic assessment of effective applicator position relative to plan, - Update of treatment plan - Automatic assessment of effective ablation volume relative to treatment plan

Award Detail

1 Cascination (Bern)
  • Reference: 031449-2022-add/pu/km/22/31-1
  • Value: £200,000

CPV Codes

  • 33110000 - Imaging equipment for medical, dental and veterinary use

Other Information

** PREVIEW NOTICE, please check Find a Tender for full details. **

Reference

Domains