22/012 - GNI (UK) Brighouse Bay Compressor Station, LV Switchgear Replacement
A Utilities Contract Award Notice
by GNI (UK) LIMITED
- Source
- OJEU
- Type
- Contract (Supply)
- Duration
- not specified
- Value
- 555K
- Sector
- INDUSTRIAL
- Published
- 24 Apr 2023
- Delivery
- not specified
- Deadline
- n/a
Concepts
Location
Kirkcudbright
2 buyers
- Gni Kirkcudbright
1 supplier
- Eaton Electrical Systems Leinster
Description
22/012 - GNI (UK) Brighouse Bay Compressor Station, LV Switchgear Replacement
Total Quantity or Scope
GNI UK Ltd acting as reasonable and prudent gas transporter are committed to operating a safe, reliable and sustainability transmission and distribution network. GNI UK own and operate the high pressure natural gas South West Scotland Onshore System (SWSOS) which connects the upstream Great Britain (GB) National Transmission System (NTS) to the Republic of Ireland (RoI), Northern Ireland (NI) and Isle of Man systems via subsea interconnector pipelines. Brighouse Bay Compressor Station (BBCS) is a critical node located on the SWSOS consisting of six (6) gas turbine compressor units which ensure safe and secure onward transportation of natural gas to the RoI transmission system and Isle of Man offtake. Brighouse Bay electrical demand is served by two (2) 11kV / 400V transformer substations, two (2) low voltage (LV) electrical switchroom / motor control centres (MCC1 and MCC2) and one standby diesel generator. MCC1 is in operation since the station was first commissioned in 1993. MCC1 electrical assets consist of one (1) main distribution switchgear panel, three (3) motor control centres panels (MCC A, B, C), one (1) large general services and lighting distribution panel and one (1) power factor correction panel. The main distribution panel also incorporates transformer protection and standby generator controls. MCC1 serves as the primary power distribution hub for the Brighouse admin and control building, utility and services building, workshops, compressor halls and is critical for the reliable operation and continuous availability of three (3) turbine compressor units (Units A, B, C). GNI UK commissioned a site wide review of the Brighouse electrical installation in 2018. Findings from the study show MCC1 electrical equipment has reached end of useful life with some functional units now obsolete. The study also highlights constraints associated with operability and functionality of the current switchgear arrangement, circuity configuration, means of isolation, and working area / operational access. The study recommends to replace and upgrade all MCC1 equipment and install a new temporary transportable generator inlet connection / changeover panel. GNI UK now wish to procure the replacement of all associated MCC1 switchgear as detailed in the BBCS switchgear specification (Ref. 18074-20-SP-0001) The specification covers the design, manufacture, factory acceptance testing, storage, handling, delivery, site re-assembly, verification testing and pre-commissioning of LV power switchgear and control gear. Equipment to be supplied includes one (1) main distribution switchgear panel, three (3) motor control centre panels (MCC), one (1) general service distribution board, one (1) power factor correction panel, and one (1) transportable generator inlet / changeover panel.
Award Detail
1 | Eaton Electrical Systems (None)
|
Award Criteria
PRICE | _ |
CPV Codes
- 31214000 - Switchgear
Indicators
- Award on basis of price.
Legal Justification
Fundamental to the successful delivery of goods or services is the economic operators ability to demonstrate the switchgear solution offered can be manufactured, delivered, reassembled and installed in accordance with BBCS switchgear specification (Ref. 18074-20-SP-0001) without the need to alter the basis of design, specification, extend or substantially reconstruct the existing building. Optimised design footprint and orientation for all switchgear assemblies is essential for installation, retermination of existing cables, future operation and maintenance due to the limited working area available. MCC1 supplies power to critical turbine compressor machinery which cannot be fully isolated for the duration of work therefore the switchgear offered must be designed and manufactured to allow for the equipment to be reassembled and installed in sequence over a phased construction period. Having conducted initial market consultation with a number of OEMs and licenced switchgear manufacturers followed by three (3) competitive procurement procedures between 2020 - 2022, Eaton Electrical Systems Limited Ireland have emerged as the only economic operator who have demonstrated capability to meet the requirements of the BBCS switchgear specification in full. Previous tender submissions and clarifications received from other tenderers failed to demonstrate or guarantee compliance with GNI UK requirements. All previous tenderers could not provide an optimised switchgear geometry tailored for site installation as per the layouts and orientation detailed in the specification. Some tender submissions did not offer withdrawable switchgear. Some tender submissions did not comply in full with internal arc fault criteria as specified.
Reference
- OJEU 241460-2023