Fire & Intruder Alarms, Sprinkler Systems and Fire Protection Equipment and Emergency Lighting Systems Framework

A Tender Notice
by EFFICIENCY EAST MIDLANDS LIMITED

Source
Find a Tender
Type
Framework (Services)
Duration
4 year
Value
£600M
Sector
INDUSTRIAL
Published
20 May 2022
Delivery
To 15 Jul 2026 (est.)
Deadline
15 Jul 2022 13:00

Concepts

Location

Alfreton

Geochart for 4 buyers and 0 suppliers

4 buyers

Description

Efficiency East Midlands Ltd (EEM) is a not for profit consortium which establishes and manages a range of framework and DPS agreements. Our membership has now grown to 261 public sector organisations including housing associations and ALMO's, Local Authorities, NHS trusts, Education Providers, Blue Light Services, Government Agencies and Charities. EEM have also established a formal collaboration with 3 like minded procurement consortia - Westworks, South East Consortium and Advantage South West. The membership list for these three consortia may be obtained from the following website addresses: www.westworks.org.uk www.southeastconsortium.org.uk www.advantagesouthwest.co.uk EEM are conducting this tender exercise to create a Fire & Intruder Alarms, Sprinkler Systems and Fire Protection Equipment, Emergency Lighting Systems Framework to replace our existing framework that will expire in 2022. The framework has been split into geographical lots: • Lot 1 - Midlands • Lot 2 - Greater London • Lot 3 - National Coverage

Lot Division

1 Fire & Intruder Alarms, Sprinkler Systems and Fire Protection Equipment and Emergency Lighting Systems Framework
  • Value: £200M

Lot 1 is being created to support Members located in the Midlands meet legal obligations to ensure compliance in meeting current legislation and guidance for fire safety system installations and maintenance. The framework will provide EEM Members with a route to procure the works listed below and maintenance will include planned and reactive maintenance. • Fire Alarm Systems Service and Maintenance (Conventional, Addressable, Analogue Addressable and Wireless). • Fire Alarm Systems Upgrades and New System Installations (Conventional, Addressable, Analogue Addressable and Wireless). • Detection Devices (Smoke, Flame, Heat, Carbon Monoxide, Multi-Sensor and Manual Call Points). • Output Devices (Warning System/Bell Relays, Door Holder Relays, Auxillary Relays, Loop Sounders) • Intruder Alarm System Installations, Upgrades, Maintenance and Repairs. • Sprinkler, Misting and Suppression Systems Retrofitting Works, New Installations, Maintenance and Repairs. • Aspirating System Installations, Upgrades, Maintenance and Repairs. • Fire Protection Equipment Supply, Maintenance, and Refill o Fire Extinguishers o Fire Hydrants o Fire Dampers o Fire Shutters o Fire Blankets o Fire Evacuation Chairs o Hose Reels, Inlets, Valves and Nozzles o Safety Signs • Dry and Wet Riser Systems, Maintenance, Repairs and System Upgrades. • Automatic Opening Vents (AOVs) Maintenance, Repairs and System Upgrades. • Fire Door Inspection Services • Emergency Lighting Systems Maintenance, Repairs and System Upgrades. • Fire and Intruder Alarm Engineers • All builders work and making good/redecoration of all building fabric disturbed by associated works. • Testing, commissioning, and system demonstrations, as fitted drawings and operation and maintenance manuals and any other works associated with contracts including any of the above-described works.

Award Criteria
Minimum Framework Requirements Assessment _
Tender Assessment Questions 40.0
Fire Alarm System Servicing and Maintenance 10.0
Intruder Alarm System Servicing and Maintenance 7.5
Sprinkler System Servicing and Maintenance 7.5
Emergency Lighting Servicing and Maintenance 7.5
Schedule of Rates 10.0
Install Scenario 2.5
Servicing Scenario 10.0
Callout and Labour Rates 5.0
2 Fire & Intruder Alarms, Sprinkler Systems and Fire Protection Equipment and Emergency Lighting Systems Framework
  • Value: £200M

Lot 2 is being created to support Members located in Greater London meet legal obligations to ensure compliance in meeting current legislation and guidance for fire safety system installations and maintenance. The framework will provide EEM Members with a route to procure the works listed below and maintenance will include planned and reactive maintenance. • Fire Alarm Systems Service and Maintenance (Conventional, Addressable, Analogue Addressable and Wireless). • Fire Alarm Systems Upgrades and New System Installations (Conventional, Addressable, Analogue Addressable and Wireless). • Detection Devices (Smoke, Flame, Heat, Carbon Monoxide, Multi-Sensor and Manual Call Points). • Output Devices (Warning System/Bell Relays, Door Holder Relays, Auxiliary Relays, Loop Sounders). • Intruder Alarm System Installations, Upgrades, Maintenance and Repairs. • Sprinkler, Misting and Suppression Systems Retrofitting Works, New Installations, Maintenance and Repairs.. • Aspirating System Installations, Upgrades, Maintenance and Repairs. • Fire Protection Equipment Supply, Maintenance, and Refill o Fire Extinguishers o Fire Hydrants o Fire Dampers o Fire Shutters o Fire Blankets o Fire Evacuation Chairs o Hose Reels, Inlets, Valves and Nozzles o Safety Signs • Dry and Wet Riser Systems, Maintenance, Repairs and System Upgrades. • Automatic Opening Vents (AOVs) Maintenance, Repairs and System Upgrades. • Fire Door Inspection Services. • Emergency Lighting Systems Maintenance, Repairs and System Upgrades. • Fire and Intruder Alarm Engineers. • All builders work and making good/redecoration of all building fabric disturbed by associated works. • Testing, commissioning, and system demonstrations, as fitted drawings and operation and maintenance manuals and any other works associated with contracts including any of the above-described works.

Award Criteria
Minimum Framework Requirements Assessment _
Tender Assessment Questions 40.0
Fire Alarm System Servicing and Maintenance 10.0
Intruder Alarm System Servicing and Maintenance 7.5
Sprinkler System Servicing and Maintenance 7.5
Emergency Lighting Servicing and Maintenance 7.5
Schedule of Rates 10.0
Install Scenario 2.5
Servicing Scenario's 10.0
Callout and Labour Rates 5.0
3 Fire & Intruder Alarms, Sprinkler Systems and Fire Protection Equipment and Emergency Lighting Systems Framework
  • Value: £200M

Lot 3 is being created to support Members located throughout England and Wales meet legal obligations to ensure compliance in meeting current legislation and guidance for fire safety system installations and maintenance. The framework will provide EEM Members with a route to procure the works listed below and maintenance will include planned and reactive maintenance. • Fire Alarm Systems Service and Maintenance (Conventional, Addressable, Analogue Addressable and Wireless). • Fire Alarm Systems Upgrades and New System Installations (Conventional, Addressable, Analogue Addressable and Wireless). • Detection Devices (Smoke, Flame, Heat, Carbon Monoxide, Multi-Sensor and Manual Call Points). • Output Devices (Warning System/Bell Relays, Door Holder Relays, Auxiliary Relays, Loop Sounders). • Intruder Alarm System Installations, Upgrades, Maintenance and Repairs. • Sprinkler, Misting and Suppression Systems Retrofitting Works, New Installations, Maintenance and Repairs. • Aspirating System Installations, Upgrades, Maintenance and Repairs. • Fire Protection Equipment Supply, Maintenance, and Refill o Fire Extinguishers o Fire Hydrants o Fire Dampers o Fire Shutters o Fire Blankets o Fire Evacuation Chairs o Hose Reels, Inlets, Valves and Nozzles o Safety Signs • Dry and Wet Riser Systems, Maintenance, Repairs and System Upgrades. • Automatic Opening Vents (AOVs) Maintenance, Repairs and System Upgrades. • Fire Door Inspection Services. • Emergency Lighting Systems Maintenance, Repairs and System Upgrades. • Fire and Intruder Alarm Engineers. • All builders work and making good/redecoration of all building fabric disturbed by associated works. • Testing, commissioning, and system demonstrations, as fitted drawings and operation and maintenance manuals and any other works associated with contracts including any of the above-described works.

Award Criteria
Minimum Framework Requirements Assessment _
Method Statement Assessment Questions 40.0
Fire Alarm System Servicing and Maintenance 10.0
Intruder Alarm System Servicing and Maintenance 7.5
Sprinkler System Servicing and Maintenance 7.5
Emergency Lighting Servicing and Maintenance 7.5
Schedule of Rates 10.0
Install Scenario 2.5
Servicing Scenario's 10.0
Callout and Labour Rates 5.0

CPV Codes

  • 50413200 - Repair and maintenance services of firefighting equipment
  • 31518200 - Emergency lighting equipment
  • 31625100 - Fire-detection systems
  • 31625200 - Fire-alarm systems
  • 31625300 - Burglar-alarm systems
  • 35111000 - Firefighting equipment
  • 39525400 - Fire blankets
  • 44115500 - Sprinkler systems
  • 44221220 - Fire doors
  • 44482100 - Fire hoses
  • 44482200 - Fire hydrants
  • 45312100 - Fire-alarm system installation work
  • 45312200 - Burglar-alarm system installation work
  • 45343100 - Fireproofing work
  • 45343200 - Firefighting equipment installation work
  • 45343210 - CO2 fire-extinguishing equipment installation work
  • 45343220 - Fire-extinguishers installation work
  • 45343230 - Sprinkler systems installation work
  • 50700000 - Repair and maintenance services of building installations
  • 51700000 - Installation services of fire protection equipment
  • 75251110 - Fire-prevention services
  • 79711000 - Alarm-monitoring services

Indicators

  • Restrictions apply to the lot award allocation.
  • Bids should cover one or more lots.
  • Bids should cover the whole contract.
  • Renewals are not available.

Other Information

The call-off contracts to be awarded pursuant to the framework agreements to be entered at conclusion of the procurement exercise may extend for a duration of up to 5 years beyond expiry of the 4-year framework term. Please note that the total potential framework value stated within this notice is in relation to the full 4-year framework and takes into consideration the lot structure, length of call off contracts and that the EEM membership may grow over the framework lifetime . Where the contract notice states a maximum of suppliers to be appointed to the Framework, this means within each lot. EEM reserves the right to appoint less than the numbers stated. This framework is being procured by Efficiency East Midlands Ltd (EEM) on behalf of their members and the other organisations described below as being authorised users. The following contracting authorities will be entitled to agree and award contracts under this framework agreement as Authorised Users: 1) any Member of EEM which for the avoidance of doubt currently includes 3 partner consortia - Westworks(www.westworks.org.uk), Advantage South West (www.advantagesouthwest.co.uk) and South East Consortium (www.southeastconsortium.org.uk). A full list of current members is available at www.eem.org.uk 2) any future member of EEM or our partner consortia and in all cases being an organisation which has applied to join EEM or our partner consortia in accordance with the applicable constitutional documents; 3) An EEM participant being an organisation which is neither a current or EEM member (as defined at 1 above) nor a future member of EEM (as defined at 2 above) . Further details regarding the authorised users of this framework can be found in the ITT documents. To respond to this tender or review the documentation, please: 1) Go to the portal https://xantive.supplierselect.com 2) If you need to register a new account follow the prompts to set up your organisation; 3) When you sign in select 'Public Projects' from the menu (top right). A list of all open tenders will be displayed; 4) Select 'EEM0067 Fire & Intruder Alarms, Sprinkler Systems and Fire Protection Equipment and Emergency Lighting Systems Framework ' from the list of projects and then 'Create Opportunity'. That will give you access to the basic information; 5) Click 'Accept Opportunity' to get more detail including all clarification logs. There is no obligation to submit a response; 6) If you do wish to submit a response, do so before the deadline by changing the status to submitted. You will only be allowed to submit if every mandatory question is answered.

Reference

Domains